SHARC & PIRANHA Customer Highlights

Interactive Customer Map

Browse this interactive partial list of SHARC & PIRANHA customers!

Looking for Customer videos?

Want to download all case studies?

SHARC Customer Projects

Project Name Equipment Quantity Use Case - Project Type Building Size Commissioned Developer Engineering Firm Architectural Firm Application Filtered Wastewater Flowrate (GPM) Design Energy Transfer (MBH) Energy Transferred (MMBTU-year) Heating-Cooling % ratio Therms natural gas avoided (therm-yr) GHG equivalent (metric t CO2e-yr) * Baseline Alternate *Baseline Alternate Efficiency Estimated water use reduction (gal-yr) Evaporation reduction from cooling tower (gal-yr) Blowdown reduction from cooling tower (gal-yr) Additional benefits * Baseline Alternate *Baseline Alternate Efficiency Auxiliary Details DHW Setpoint Temp (°F) Approx DHW Load (%) Net Energy Reduction (MWh-year) Energy Reduction vs. Baseline GHG Emission Reduction (t CO2e-year) *Baseline Baseline Efficiency Auxiliary Benefits? Ie. freshwater savings potential Notes
Sail SHARC 660 System 1 Multi-Family Residential 172 Units Fall 2013 - - - DHW 150 338* HX - - - - - - - - - - - - Heat Pumps 2-qty Colmac HPW9 - 18 ton total 120 80 - - - Natural Gas - -
Wall Center Phase 1 SHARC 660 System 1 Multi-Family Residential 728 Units August 2017 Wall Financial Corporation Sterling Cooper Consultants GBL Architects DHW 100 300* HX 4,073 MMBTU-yr 100%-0% 47,920 therm-yr 259 Natural Gas 85 - - - - - - Heat Pumps Colmac HPW24M - 2-qty 12 ton modules - 24 ton total 120 30 - - - Natural Gas - -
False Creek NEU SHARC 880 System 2 District Energy - March 2017 City of Vancouver City of Vancouver City of Vancouver Wastewater Filter Only 2000 - - - - - - - - - - - - - - - - - - - - - -
DC Water HQ SHARC 660 System 1 Commercial 151,300 ft2 August 2018 DC Water Smithgroup Smithgroup Heating-Cooling 250 Summer - 2,540 Winter - 1,653 6,712 MMBTU-yr 3.3%-96.7% 2,320 therm-yr 12.6 Natural Gas 95% (at optimum condensing) 1.5 million gal-yr 1.0 million gal-yr 0.5 million gal-yr Improved cooling loop temperature and electricity reduction cooling tower - Heat Pumps; unknown heat pumps; - - 2,980 - 153 Natural gas (heating); - freshwater savings w- cooling tower offset
National Western Center SHARC 880 System 2 District Energy - April 2022 National Western Center - - DHW 3000 19,750 19,750,000 100% - 0% - - Natural Gas 85 - - - - - - - - - - - - - - - -

PIRANHA Customer Projects

Project Name Equipment Quantity Use Case / Project Type Building Size Commissioned Developer Engineering Firm Architectural Firm Application DHW Setpoint Temp (°F) Approx DHW Load (%) Design Energy Output (MBH) Average PIRANHA Efficiency Net Energy Reduction (MMBTU/year) Energy Reduction vs. Baseline Therms of Fossil Fuels avoided GHG Emission Reduction *Baseline *Baseline Efficiency Approximate Impact Auxiliary Benefits? Ie. freshwater savings potential
Seven35 PIRANHA T10 HC 1 Multi-Family Residential 60 Units June 2012 - SHARC 660 April 2016 - PIRANHA T10 March 2020 - PIRANHA T10 HC Adera Stantec Consulting Ltd. Integra Architecture DHW + Cooling 140°F / 60°C 100 120 3.7 720 78 9,350 49.6 Natural Gas 85 - - approx 96 MBH cooling capacity
Lake Louise PIRANHA T10 1 Hospitality & Laundry 247 Rooms 18-Sep - - - DHW 120°F / 49°C 50 120 5.25 685 44 7,730 35 Propane 60 - - -
3200 Bluff PIRANHA T5 1 Multi-Family Residential 37 Units - - - - DHW 120°F / 50°C 80% 120 3.25 89 44 - 53.8 Propane - - - -

Contact Form